{"title":"Clearance","description":"","products":[{"product_id":"cube-350-energy-power-multi-function-sub-meter-three-phase","title":"Cube 350- 230V Energy \u0026 Power Multi-Function Sub-meter (Three Phase)","description":"\u003cp\u003eDon’t let the simple looks of the Cube 350 fool you, this is a powerful, feature-rich multi-function meter. The Cube 350 has been the mainstay of some of the largest and most successful sub-metering rollouts globally. The Cube 350’s ‘Right First time’ setup includes features like the Phase Indicator LEDs and the Auto-Rotation functionality for CTs for right first-time set-up. This effort to minimize and correct any installation issues, married to the 5-year warranty and extensive data sets available via the MODBUS \u0026amp; IP Ethernet communications options make this a perfect meter for sub-metering rollouts.\u003c\/p\u003e\n\u003cp\u003eThe Cube 350’s communication options are pulse output only, RS485 MODBUS \u0026amp; IP Ethernet offering TCP\/IP protocols such as HTTP, FTP, TFTP, SNMP. The various TCP\/IP protocols make this the ideal meter to interface directly with energy management software and building control solutions, without the need for data loggers or concentrators. The web pages on the IP Ethernet enabled Cube 350 allow the user to view important instantaneous values and access the setup pages should the need arise to change any of the parameters.\u003c\/p\u003e","brand":"CHK Shop","offers":[{"title":"Cube 350-333mV-230V","offer_id":43670418489409,"sku":"1DNDCub35-Mod1","price":225.0,"currency_code":"AUD","in_stock":true},{"title":"Cube 350-333mV-230V-Modbus","offer_id":43670418522177,"sku":"1DNDCub35-Mod2","price":285.0,"currency_code":"AUD","in_stock":true},{"title":"Cube 350-333mV-230V-Modbus + Harmonics","offer_id":43670418554945,"sku":"1DNDCub35-Mod3","price":320.0,"currency_code":"AUD","in_stock":true},{"title":"Cube 350-333mV-230V-Ethernet + Others","offer_id":43670418587713,"sku":"1DNDCub35-Mod4","price":465.0,"currency_code":"AUD","in_stock":true},{"title":"Cube 350-333mV-230V+48V\/23V Aux","offer_id":43670418620481,"sku":"1DNDCub35-Mod5","price":175.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/6667\/7825\/files\/Cube-350.jpg?v=1761716225"},{"product_id":"multicube-modular-meter-expandable-multi-channel-multi-function-sub-meter","title":"MultiCube Modular Meter Expandable Multi-Channel Multi-Function Sub-meter","description":"\u003cp\u003eThe MultiCube Modular Meter is a metering system designed for applications where multiple meters need to be installed. It provides a high-density system with simplified wiring and advanced features. Its modular design allows for future expansion if required and its autorotation feature allows the meter to correct for any current transformers which may have been installed the wrong way around.\u003c\/p\u003e\n\u003cp\u003eIf you are looking for a multiple metering solution which is space efficient, time efficient to install and setup, and future-proofs any installation for expansion then the MultiCube is the solution. One display and one communication port access and configures all Meter Modules. Meter System \u0026amp; Meter Channels can store Real-World Names e.g Outside Lighting. MultiCube’s flexible design permits configuration and expansion from 1 to 10-meter modules. Single Modbus request to ‘master’ will return energies from ALL slaves, allowing extremely fast response times – ideal for real-time monitoring.\u003c\/p\u003e","brand":"CHK Shop","offers":[{"title":"Default Title","offer_id":42991747137601,"sku":"CHKMT0006","price":500.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/6667\/7825\/files\/MultiCube-Modular-Meter.avif?v=1761716825"},{"product_id":"rail-310-energy-power-multi-function-sub-meter-single-phase","title":"Rail 310 Energy \u0026 Power Multi-Function Sub-meter (Single Phase)","description":"\u003cp\u003e\u003cspan\u003e3 kWh Meters in a single DIN Rail mounting. Easy to install and convenient to use. These meters have been designed to measure accurately irrespective of the type of load. Ideal for modern electronically controlled loads.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThere are different variants to choose from: \u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cstrong\u003eClick on Request to Quote\u003c\/strong\u003e\u003c\/span\u003e for a better deal.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable height=\"391\" style=\"border-collapse: collapse; width: 472px;\" width=\"266\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e\n\u003ccol style=\"width: 253px;\" width=\"151\"\u003e \u003ccol style=\"width: 218px;\" width=\"115\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 14.6pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.6pt; width: 114pt;\" width=\"151\" class=\"xl65\" height=\"19\"\u003eRail 310-5A-230V\u003c\/td\u003e\n\u003ctd style=\"border-left: none; width: 87pt;\" width=\"115\" class=\"xl65\"\u003e1DNDRL31-Mod1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.6pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.6pt; border-top: none; width: 114pt;\" width=\"151\" class=\"xl65\" height=\"19\"\u003eRail310-5A-230V-Modbus\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 87pt;\" width=\"115\" class=\"xl65\"\u003e1DNDRL31-Mod2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.6pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.6pt; border-top: none; width: 114pt;\" width=\"151\" class=\"xl65\" height=\"19\"\u003eRail 310-5A-110V\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 87pt;\" width=\"115\" class=\"xl65\"\u003e1DNDRL31-Mod3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.6pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.6pt; border-top: none; width: 114pt;\" width=\"151\" class=\"xl65\" height=\"19\"\u003eRail 310-5A-110V-Modbus\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 87pt;\" width=\"115\" class=\"xl65\"\u003e1DNDRL31-Mod4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.6pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.6pt; border-top: none; width: 114pt;\" width=\"151\" class=\"xl65\" height=\"19\"\u003eRail 310-1A-230V\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 87pt;\" width=\"115\" class=\"xl65\"\u003e1DNDRL31-Mod5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.6pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.6pt; border-top: none; width: 114pt;\" width=\"151\" class=\"xl65\" height=\"19\"\u003eRail310-1A-230V-Modbus\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 87pt;\" width=\"115\" class=\"xl65\"\u003e1DNDRL31-Mod6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.6pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.6pt; border-top: none; width: 114pt;\" width=\"151\" class=\"xl65\" height=\"19\"\u003eRail 310-1A-110V\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 87pt;\" width=\"115\" class=\"xl65\"\u003e1DNDRL31-Mod7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.6pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.6pt; border-top: none; width: 114pt;\" width=\"151\" class=\"xl65\" height=\"19\"\u003eRail 310-1A-110V-Modbus\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 87pt;\" width=\"115\" class=\"xl65\"\u003e1DNDRL31-Mod8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.6pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.6pt; border-top: none; width: 114pt;\" width=\"151\" class=\"xl65\" height=\"19\"\u003eRail 310-333mV-230V\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 87pt;\" width=\"115\" class=\"xl65\"\u003e1DNDRL31-Mod9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.6pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.6pt; border-top: none; width: 114pt;\" width=\"151\" class=\"xl65\" height=\"19\"\u003eRail310-333mV-230V-Modbus\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 87pt;\" width=\"115\" class=\"xl65\"\u003e1DNDRL31-Mod10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.6pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.6pt; border-top: none; width: 114pt;\" width=\"151\" class=\"xl65\" height=\"19\"\u003eRail 310-333mV-110V\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 87pt;\" width=\"115\" class=\"xl65\"\u003e1DNDRL31-Mod11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 14.6pt;\" height=\"19\"\u003e\n\u003ctd style=\"height: 14.6pt; border-top: none; width: 114pt;\" width=\"151\" class=\"xl65\" height=\"19\"\u003eRail 310-333mV-110V-Modbus\u003c\/td\u003e\n\u003ctd style=\"border-top: none; border-left: none; width: 87pt;\" width=\"115\" class=\"xl65\"\u003e1DNDRL31-Mod12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"CHK Shop","offers":[{"title":"Default Title","offer_id":42991750250561,"sku":"CHKMT0005","price":350.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/6667\/7825\/files\/Rail-310.avif?v=1761716983"},{"product_id":"rail-350-energy-power-multi-function-sub-meter-three-phase","title":"Rail 350 Energy \u0026 Power Multi-Function Sub-meter (Three Phase)","description":"\u003cp\u003eDon’t let the simple looks of the Rail 350 fool you, this is a powerful, feature rich multi function meter.\u003c\/p\u003e\n\u003cp\u003eThe Rail 350’s ‘Right First time’ setup includes the Auto Rotation functionality for CTs for right first time set up. This effort to minimize and correct any installation issues, married to the 5 year warranty and extensive data sets available via the MODBUS \u0026amp; IP Ethernet communications options make this a perfect meter for sub metering rollouts.\u003c\/p\u003e\n\u003cp\u003eThere are different variants to choose from: \u003cspan style=\"color: rgb(255, 42, 0);\"\u003e\u003cstrong\u003eClick on Request to Quote\u003c\/strong\u003e\u003c\/span\u003e for a better deal.\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"266\" style=\"border-collapse: collapse; width: 474px;\" height=\"575\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"151\" style=\"width: 254.5px;\"\u003e \u003ccol width=\"115\" style=\"width: 219.5px;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl67\" width=\"151\" style=\"height: 14.6pt; width: 114pt;\"\u003eRail 350-5A-230V\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"115\" style=\"border-left: none; width: 87pt;\"\u003e1DNDRL35-Mod1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl67\" width=\"151\" style=\"height: 14.6pt; border-top: none; width: 114pt;\"\u003eRail 350-5A-230V-Modbus\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"115\" style=\"border-top: none; border-left: none; width: 87pt;\"\u003e1DNDRL35-Mod2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl67\" width=\"151\" style=\"height: 14.6pt; border-top: none; width: 114pt;\"\u003eRail 350-5A-230V-48\/24V\u003cspan style=\"mso-spacerun: yes;\"\u003e \u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"115\" style=\"border-top: none; border-left: none; width: 87pt;\"\u003e1DNDRL35-Mod3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl67\" width=\"151\" style=\"height: 14.6pt; border-top: none; width: 114pt;\"\u003eRail 350-5A-110V\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"115\" style=\"border-top: none; border-left: none; width: 87pt;\"\u003e1DNDRL35-Mod4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl67\" width=\"151\" style=\"height: 14.6pt; border-top: none; width: 114pt;\"\u003eRail 350-5A-110V-Modbus\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"115\" style=\"border-top: none; border-left: none; width: 87pt;\"\u003e1DNDRL35-Mod5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"29\" style=\"height: 21.45pt;\"\u003e\n\u003ctd height=\"29\" class=\"xl67\" width=\"151\" style=\"height: 21.45pt; border-top: none; width: 114pt;\"\u003eRail 350-5A-110V-Modbus-48\/24V\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"115\" style=\"border-top: none; border-left: none; width: 87pt;\"\u003e1DNDRL35-Mod6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl67\" width=\"151\" style=\"height: 14.6pt; border-top: none; width: 114pt;\"\u003eRail 350-1A-230V\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"115\" style=\"border-top: none; border-left: none; width: 87pt;\"\u003e1DNDRL35-Mod7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl67\" width=\"151\" style=\"height: 14.6pt; border-top: none; width: 114pt;\"\u003eRail 350-1A-230V-Modbus\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"115\" style=\"border-top: none; border-left: none; width: 87pt;\"\u003e1DNDRL35-Mod8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"29\" style=\"height: 21.45pt;\"\u003e\n\u003ctd height=\"29\" class=\"xl67\" width=\"151\" style=\"height: 21.45pt; border-top: none; width: 114pt;\"\u003eRail 350-1A-230V-Modbus-48\/24V\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"115\" style=\"border-top: none; border-left: none; width: 87pt;\"\u003e1DNDRL35-Mod9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl67\" width=\"151\" style=\"height: 14.6pt; border-top: none; width: 114pt;\"\u003eRail 350-1A-110V\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"115\" style=\"border-top: none; border-left: none; width: 87pt;\"\u003e1DNDRL35-Mod10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl67\" width=\"151\" style=\"height: 14.6pt; border-top: none; width: 114pt;\"\u003eRail 350-1A-110V-Modbus\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"115\" style=\"border-top: none; border-left: none; width: 87pt;\"\u003e1DNDRL35-Mod11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"29\" style=\"height: 21.45pt;\"\u003e\n\u003ctd height=\"29\" class=\"xl67\" width=\"151\" style=\"height: 21.45pt; border-top: none; width: 114pt;\"\u003eRail 350-1A-110V-Modbus-48\/24V\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"115\" style=\"border-top: none; border-left: none; width: 87pt;\"\u003e1DNDRL35-Mod12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl67\" width=\"151\" style=\"height: 14.6pt; border-top: none; width: 114pt;\"\u003eRail 350-333mV-230V\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"115\" style=\"border-top: none; border-left: none; width: 87pt;\"\u003e1DNDRL35-Mod13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl67\" width=\"151\" style=\"height: 14.6pt; border-top: none; width: 114pt;\"\u003eRail 350-333mV-230V-Modbus\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"115\" style=\"border-top: none; border-left: none; width: 87pt;\"\u003e1DNDRL35-Mod14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl67\" width=\"151\" style=\"height: 14.6pt; border-top: none; width: 114pt;\"\u003eRail 350-333mV-110V\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"115\" style=\"border-top: none; border-left: none; width: 87pt;\"\u003e1DNDRL35-Mod15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl67\" width=\"151\" style=\"height: 14.6pt; border-top: none; width: 114pt;\"\u003eRail 350-333mV-110V-Modbus\u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"115\" style=\"border-top: none; border-left: none; width: 87pt;\"\u003e1DNDRL35-Mod16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"CHK Shop","offers":[{"title":"Default Title","offer_id":42991862906945,"sku":null,"price":350.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/6667\/7825\/files\/Rail-350.avif?v=1761717172"},{"product_id":"pmc-592-multi-circuit-power-monitor","title":"PMC-592 Multi-Circuit Power Monitor","description":"\u003cp\u003eThe PMC-592 MCPM is the ultimate solution for PDU, LVDB and Load Center applications that require multi-circuit monitoring. Housed in a compact metal enclosure, the PMC-592 is perfectly suited for applications that require high density metering. The PMC-592 features quality construction with multifunction and High-Accuracy measurements, two Mains Inputs, up to 84 Branch Circuit Inputs and an optional 7” Touch-Screen HMI. The PMC592 comes standard with two Digital Inputs for status monitoring, two Digital Outputs for control or alarming as well as two RTD Inputs for temperature measurements.\u003c\/p\u003e\n\u003cp\u003eThe standard SOE Log records all setup changes, Setpoint alarms and DI\/DO operations in 1ms resolution. With Ethernet and dual RS-485 as standard feature supporting Modbus RTU\/TCP, HTTP, SMTP as well as SNMP, the PMC-592 becomes a vital component of an intelligent, multiccircuit monitoring solution.\u003c\/p\u003e","brand":"CHK Shop","offers":[{"title":"Default Title","offer_id":42991926149185,"sku":"1DCET592","price":1340.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/6667\/7825\/files\/PMC-592-3.webp?v=1761718018"},{"product_id":"cat-iv-600v-flexible-current-probes-blue","title":"CAT IV 600V Flexible Current Probes (Blue)","description":"\u003cp data-start=\"20\" data-end=\"221\"\u003eThe CAT IV 600V Flexible Current Probes are high performance current sensors designed as accessories for CHK Power Quality instruments used on energised circuits and in CAT IV environments.\u003c\/p\u003e\n\u003cp data-start=\"223\" data-end=\"586\"\u003eThese flexible Rogowski-type current probes provide safe and accurate current measurement in demanding field applications such as power quality monitoring, energy studies, and compliance testing. The flexible coil design allows easy installation around busbars, large conductors, or confined switchboard spaces where conventional clamp CTs cannot be used.\u003c\/p\u003e\n\u003cp data-start=\"588\" data-end=\"642\"\u003eThe probes are available with two connector options:\u003c\/p\u003e\n\u003cul data-start=\"643\" data-end=\"839\"\u003e\n\u003cli data-start=\"643\" data-end=\"748\"\u003e\n\u003cp data-start=\"645\" data-end=\"748\"\u003eType A connector – compatible with PQ35 series and Mirrin instruments from CHK Power Quality.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"749\" data-end=\"839\"\u003e\n\u003cp data-start=\"751\" data-end=\"839\"\u003eB-code connector – compatible with the Miro PQ45 series power quality analysers.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"841\" data-end=\"1178\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eIf required, the probes can also be supplied with tinned termination ends, allowing easy integration with third-party measurement equipment, power quality analysers, data loggers, or protection testing instruments. This provides flexibility for users who need to interface the probes with other monitoring or measurement systems.\u003c\/p\u003e","brand":"My Store","offers":[{"title":"Blue \/ 350mm \/ A code ultraloc","offer_id":43606898081857,"sku":"1AFF3000-6-SA","price":459.0,"currency_code":"AUD","in_stock":true},{"title":"Blue \/ 350mm \/ B code ultraloc","offer_id":43606898114625,"sku":"1AF3000-3","price":459.0,"currency_code":"AUD","in_stock":true},{"title":"Blue \/ 350mm \/ A code screw type connector","offer_id":43606898147393,"sku":"1AFF3000-3","price":459.0,"currency_code":"AUD","in_stock":true},{"title":"Blue \/ 350mm \/ B code screw type connector","offer_id":43606898180161,"sku":"1AF3000-3","price":459.0,"currency_code":"AUD","in_stock":true},{"title":"Blue \/ 350mm \/ Tinned end","offer_id":43606898212929,"sku":"1AFF3000-3-TE","price":420.0,"currency_code":"AUD","in_stock":true},{"title":"Blue \/ 600mm \/ A code ultraloc","offer_id":43606898245697,"sku":"1AFF3000-6","price":459.0,"currency_code":"AUD","in_stock":true},{"title":"Blue \/ 600mm \/ B code ultraloc","offer_id":43606898278465,"sku":"1AF3000-6","price":459.0,"currency_code":"AUD","in_stock":true},{"title":"Blue \/ 600mm \/ A code screw type connector","offer_id":43606898311233,"sku":"1AFF3000-6","price":459.0,"currency_code":"AUD","in_stock":true},{"title":"Blue \/ 600mm \/ B code screw type connector","offer_id":43606898344001,"sku":"1AF3000-6","price":459.0,"currency_code":"AUD","in_stock":true},{"title":"Blue \/ 600mm \/ Tinned end","offer_id":43606898376769,"sku":"1AFF3000-6-TE","price":420.0,"currency_code":"AUD","in_stock":true},{"title":"Blue \/ 900mm \/ A code ultraloc","offer_id":43606898409537,"sku":"1AFF3000-9-SA","price":640.0,"currency_code":"AUD","in_stock":true},{"title":"Blue \/ 900mm \/ B code ultraloc","offer_id":43606898442305,"sku":"1AF3000-9-SA","price":640.0,"currency_code":"AUD","in_stock":true},{"title":"Blue \/ 900mm \/ A code screw type connector","offer_id":43606898475073,"sku":"1AFF3000-9","price":640.0,"currency_code":"AUD","in_stock":true},{"title":"Blue \/ 900mm \/ B code screw type connector","offer_id":43606898507841,"sku":"1AF3000-9","price":640.0,"currency_code":"AUD","in_stock":true},{"title":"Blue \/ 900mm \/ Tinned end","offer_id":43606898540609,"sku":"1AFF3000-9-TE","price":590.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/6667\/7825\/files\/Flexible-Rogowski-Coil-Blue.webp?v=1764755588"},{"product_id":"mc4-solar-fuse-connector","title":"MC4 solar fuse connector","description":"\u003cp\u003eThis high voltage MC4 compatible solar fuse connector delivers reliable overcurrent protection for photovoltaic (PV) systems up to 1000 VDC–1500 VDC. Designed with an interchangeable 10×38 mm fuse (rated up to 30 A), the inline connector safeguards solar panels, inverters, and DC circuitry from overload currents and fault conditions.\u003c\/p\u003e\n\u003cp\u003eBuilt for outdoor PV installations, it features robust UV resistant materials and IP67-level waterproofing, making it suitable for long-term exposure in harsh environments. The fuse can be quickly and easily replaced on site without special tools, and the MC4 style male\/female connections ensure secure, tool free engagement with standard solar cables (2.5 mm²–6 mm²).\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cem\u003eType:\u003cspan\u003e \u003c\/span\u003e\u003c\/em\u003eMC4 Compatible, fuse replaceable\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003eSize of inner fuse:\u003cspan\u003e \u003c\/span\u003e\u003c\/em\u003e10x85mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003eRated Voltage:\u003cspan\u003e \u003c\/span\u003e\u003c\/em\u003e1500VDC\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003eRated Current:\u003cspan\u003e \u003c\/span\u003e\u003c\/em\u003e35A\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003eRange of fuse ampere:\u003cspan\u003e \u003c\/span\u003e\u003c\/em\u003e2A,3A,4A,5A,6A,8A,10A, 12A,15A,16A,20A,25A, 30A,32A,35A\u003c\/li\u003e\n\u003cli\u003e\n\u003cem\u003eAmbient Temperature:\u003cspan\u003e \u003c\/span\u003e\u003c\/em\u003e-40℃~100℃\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"CHK Shop","offers":[{"title":"Default Title","offer_id":43629849575489,"sku":"CHK1500VDC MC4","price":16.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/6667\/7825\/files\/FuseholderMC4.jpg?v=1772449126"},{"product_id":"cativ-600v-large-clamp","title":"CATIV 600V Large clamp","description":"\u003cp data-start=\"199\" data-end=\"534\"\u003eThe CHK Large Voltage Clamp Assembly is a rugged, high safety connection solution designed for demanding outdoor and utility environments. Engineered for CAT IV 600V applications, this clamp is ideal for overhead line monitoring, metal busbar clamping, and temporary voltage measurement installations in harsh field conditions.\u003c\/p\u003e\n\u003cp data-start=\"536\" data-end=\"860\"\u003eManufactured using V0 flame retardant, UV stabilised materials, the assembly ensures long term durability, electrical safety, and resistance to environmental degradation. All metallic components are designed with non rust capability, making it suitable for pole top, substation, and industrial outdoor installations.\u003c\/p\u003e\n\u003cp data-start=\"862\" data-end=\"1172\"\u003eThe clamp is supplied with a 500mm multi contact 2.5mm² double-insulated V0-rated cable, providing enhanced mechanical strength and operator safety. The lead is terminated with a CAT IV 600V female banana socket, allowing secure and flexible connection to compatible male banana plug voltage terminals.\u003c\/p\u003e\n\u003cp data-start=\"1174\" data-end=\"1373\"\u003eWhen paired with a suitable CAT IV rated male banana plug, the assembly can be used for multi purpose voltage measurement, commissioning, fault diagnostics, and power quality monitoring applications.\u003c\/p\u003e","brand":"CHK Shop","offers":[{"title":"Black","offer_id":43633941807169,"sku":"1AAC1NCL\/BK- New","price":90.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/6667\/7825\/files\/Largevoltageclamp500mm2.5sqmmcabledoubleinsulated.png?v=1772520005"},{"product_id":"miro-pq45-class-a-power-quality-logger-and-analyser-kit-standard","title":"Miro PQ45- Class A Power Quality logger and Analyser (Kit-Standard)","description":"\u003cp data-start=\"171\" data-end=\"231\"\u003eThe MIRO PQ45 is supplied as a complete kit, including all accessories required for IEC 61000-4-30 Class A compliant power quality measurements. From the accessory options, you can select either high sensitivity Rogowski coils for low current measurements or standard coils for general applications.\u003c\/p\u003e\n\u003cp data-start=\"171\" data-end=\"231\"\u003eMiro PQ45 – 600V Class A Power Quality Analyser \u0026amp; Logger\u003c\/p\u003e\n\u003cp data-start=\"233\" data-end=\"652\"\u003eThe Miro PQ45  packaged with rugged holster is a truly robust and professional grade power quality analyser designed for real-world electrical systems and compliance testing. Built to IEC61000-4-30 Class A standards and rated CAT IV 600 V, this compact unit delivers the accuracy and safety you expect for power quality audits, compliance verification, energy studies and detailed waveform analysis. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"654\" data-end=\"1044\"\u003eThis isn’t just a data logger ,the PQ45 captures comprehensive measurements across all three phases plus ground and neutral, giving you a clear picture of system performance. It tracks sags, swells, interruptions and flicker, records harmonics and interharmonics, and logs voltage, current, frequency and power metrics with high precision. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1046\" data-end=\"1407\"\u003eDesigned to withstand tough environments, the unit is weatherproof (IP66) and rugged enough for outdoor installations, field testing or industrial sites. Onboard communications include Wi-Fi and optional cellular connectivity, so you can access live data or download results without hauling the unit back to the office. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1409\" data-end=\"1704\"\u003eWhether you are resolving customer complaints, validating compliance, performing energy audits, or investigating elusive power quality issues, the Miro PQ45 gives you the confidence of accurate, industry proven measurement in a portable, durable package.\u003c\/p\u003e","brand":"My Store","offers":[{"title":"4 x 1AF3000-6-H - 600mm High sensitive dual range coils 50-500A: 500-3000A","offer_id":43644878127169,"sku":"1APQ45-K1","price":13121.0,"currency_code":"AUD","in_stock":true},{"title":"4 x 1AF3000-6-H - 600mm normal sensitive range coils 300-3000A","offer_id":43644878159937,"sku":"1APQ45-K2","price":12652.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/6667\/7825\/files\/Miro45-05.jpg?v=1772087740"},{"product_id":"cube-350-110v-energy-power-multi-function-sub-meter-three-phase-copy","title":"Cube 350- 110V Energy \u0026 Power Multi-Function Sub-meter","description":"\u003cp\u003eDon’t let the simple looks of the Cube 350 fool you, this is a powerful, feature-rich multi-function meter. The Cube 350 has been the mainstay of some of the largest and most successful sub-metering rollouts globally. The Cube 350’s ‘Right First time’ setup includes features like the Phase Indicator LEDs and the Auto-Rotation functionality for CTs for right first-time set-up. This effort to minimize and correct any installation issues, married to the 5-year warranty and extensive data sets available via the MODBUS \u0026amp; IP Ethernet communications options make this a perfect meter for sub-metering rollouts.\u003c\/p\u003e\n\u003cp\u003eThe Cube 350’s communication options are pulse output only, RS485 MODBUS \u0026amp; IP Ethernet offering TCP\/IP protocols such as HTTP, FTP, TFTP, SNMP. The various TCP\/IP protocols make this the ideal meter to interface directly with energy management software and building control solutions, without the need for data loggers or concentrators. The web pages on the IP Ethernet enabled Cube 350 allow the user to view important instantaneous values and access the setup pages should the need arise to change any of the parameters.\u003c\/p\u003e","brand":"CHK Shop","offers":[{"title":"Cube 350-333mV-110V","offer_id":43670613524545,"sku":"1DNDCub35-Mod6","price":235.0,"currency_code":"AUD","in_stock":true},{"title":"Cube 350-333mV-110V-Modbus","offer_id":43670613557313,"sku":"1DNDCub35-Mod7","price":285.0,"currency_code":"AUD","in_stock":true},{"title":"Cube 350-333mV-110V-Modbus + Harmonics","offer_id":43670613590081,"sku":"1DNDCub35-Mod8","price":320.0,"currency_code":"AUD","in_stock":true},{"title":"Cube 350-333mV-110V-Ethernet + Others","offer_id":43670613622849,"sku":"1DNDCub35-Mod9","price":560.0,"currency_code":"AUD","in_stock":true},{"title":"Cube 350-333mV-110V-48V\/24V Aux","offer_id":43670613655617,"sku":"1DNDCub35-Mod10","price":175.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/6667\/7825\/files\/Cube-350.jpg?v=1761716225"},{"product_id":"miro-pq45-4g-class-a-power-quality-logger-and-analyser-4g-kit-standard","title":"Miro PQ45 -4G- Class A Power Quality logger and Analyser (4G Kit-Standard)","description":"\u003cp data-start=\"171\" data-end=\"231\"\u003eThe MIRO PQ45 is supplied as a complete kit, including all accessories required for IEC 61000-4-30 Class A compliant power quality measurements. From the accessory options, you can select either high sensitivity Rogowski coils for low current measurements or standard coils for general applications.\u003c\/p\u003e\n\u003cp data-start=\"171\" data-end=\"231\"\u003eMiro PQ45 – 600V Class A Power Quality Analyser \u0026amp; Logger\u003c\/p\u003e\n\u003cp data-start=\"233\" data-end=\"652\"\u003eThe Miro PQ45  packaged with rugged holster is a truly robust and professional grade power quality analyser designed for real-world electrical systems and compliance testing. Built to IEC61000-4-30 Class A standards and rated CAT IV 600 V, this compact unit delivers the accuracy and safety you expect for power quality audits, compliance verification, energy studies and detailed waveform analysis. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"654\" data-end=\"1044\"\u003eThis isn’t just a data logger ,the PQ45 captures comprehensive measurements across all three phases plus ground and neutral, giving you a clear picture of system performance. It tracks sags, swells, interruptions and flicker, records harmonics and interharmonics, and logs voltage, current, frequency and power metrics with high precision. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1046\" data-end=\"1407\"\u003eDesigned to withstand tough environments, the unit is weatherproof (IP66) and rugged enough for outdoor installations, field testing or industrial sites. Onboard communications include Wi-Fi and optional cellular connectivity, so you can access live data or download results without hauling the unit back to the office. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1409\" data-end=\"1704\"\u003eWhether you are resolving customer complaints, validating compliance, performing energy audits, or investigating elusive power quality issues, the Miro PQ45 gives you the confidence of accurate, industry proven measurement in a portable, durable package.\u003c\/p\u003e\n\u003cp data-start=\"1409\" data-end=\"1704\"\u003eVariants:\u003c\/p\u003e\n\u003cp data-start=\"32\" data-end=\"68\"\u003e\u003cstrong data-start=\"32\" data-end=\"68\"\u003eMiro PQ45-4G Communication Options\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"70\" data-end=\"185\"\u003eWith low speed WiFi, the unit can be configured onsite via the MIRO App (download from \u003ca href=\"www.chkpowerquality.com.au\" target=\"_blank\" title=\"CHK Power Quality website\" rel=\"noopener\"\u003ewww.chkpowerquality.com.au\u003c\/a\u003e\u003c\/p\u003e\n\u003cp data-start=\"187\" data-end=\"322\"\u003eWithout WiFi, it uses 4G for remote communication only. Local configuration and data download are still possible via USB in both cases.\u003c\/p\u003e\n\u003cp data-start=\"187\" data-end=\"322\"\u003eThe 4G enabled MIRO PQ45 is supplied with a flat mounted, universal orientation 4G antenna for flexible installation.\u003c\/p\u003e","brand":"My Store","offers":[{"title":"4 x 1AF3000-6-H - 600mm High sensitive dual range coils 50-500A: 500-3000A \/ 4G with low speed WIFI","offer_id":43706987806785,"sku":"1APQ45-K1","price":14121.0,"currency_code":"AUD","in_stock":true},{"title":"4 x 1AF3000-6-H - 600mm High sensitive dual range coils 50-500A: 500-3000A \/ 4G without low speed WIFI","offer_id":43706991280193,"sku":null,"price":13900.0,"currency_code":"AUD","in_stock":true},{"title":"4 x 1AF3000-6-H - 600mm normal sensitive range coils 300-3000A \/ 4G with low speed WIFI","offer_id":43706987839553,"sku":"1APQ45-K2","price":13652.0,"currency_code":"AUD","in_stock":true},{"title":"4 x 1AF3000-6-H - 600mm normal sensitive range coils 300-3000A \/ 4G without low speed WIFI","offer_id":43706991312961,"sku":null,"price":13520.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/6667\/7825\/files\/Miro45-05.jpg?v=1772087740"},{"product_id":"kyoritsu-6516bt-multifunction-tester","title":"Kyoritsu 6516BT Multifunction Tester","description":"\u003cp data-start=\"0\" data-end=\"309\"\u003eThe Kyoritsu 6516BT Multifunction Tester is a versatile all in one electrical installation tester designed for professional electricians, switchboard builders, inspectors, and maintenance technicians who require fast and reliable verification of electrical installations in accordance with safety standards.\u003c\/p\u003e\n\u003cp data-start=\"311\" data-end=\"696\"\u003eCombining multiple testing functions into a single portable unit, the 6516BT simplifies commissioning, troubleshooting, and routine inspection work across residential, commercial, and industrial electrical systems. The built in Bluetooth functionality allows test results to be transferred wirelessly to a smartphone or tablet for easier reporting and record management in the field.\u003c\/p\u003e\n\u003cp data-start=\"698\" data-end=\"1092\"\u003eThe instrument supports insulation resistance testing, continuity testing, loop impedance, PSC\/PFC measurement, RCD testing, voltage checks, and phase rotation verification, making it an ideal solution for complete installation testing and compliance verification. Its rugged design, intuitive interface, and large backlit display make it practical for both site and maintenance environments.\u003c\/p\u003e\n\u003cp data-start=\"698\" data-end=\"1092\"\u003e\u003cimg src=\"https:\/\/www.kew-ltd.co.jp\/en\/files\/co\/en\/img\/product_img\/6516%20function12.png\" width=\"398\" height=\"254\" style=\"display: block; margin-left: auto; margin-right: auto;\"\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"1188\" style=\"border-collapse: collapse; width: 892pt; height: 626.986px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"297\" style=\"mso-width-source: userset; mso-width-alt: 10240; width: 223pt;\"\u003e \u003ccol width=\"891\" style=\"mso-width-source: userset; mso-width-alt: 30720; width: 669pt;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"19\" style=\"height: 19.5933px;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"297\" style=\"height: 19.5933px; width: 223pt;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"891\" style=\"border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 669pt; height: 19.5933px;\"\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.5933px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 19.5933px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 223pt;\"\u003eInsulation resistance \/ SPD (Varistor)\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"891\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 669pt; height: 19.5933px;\"\u003eTest voltage: 100V \/ 250V \/ 500V \/ 1000V \/ Max.1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.5933px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 19.5933px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 223pt;\"\u003eMeasuring ranges\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"891\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 669pt; height: 19.5933px;\"\u003e2.000\/20.00\/200.0MΩ, 20.00\/200.0\/1000MΩ, 20.00\/200.0\/2000MΩ, 0 to 1049V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.5933px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 19.5933px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 223pt;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"891\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 669pt; height: 19.5933px;\"\u003e±2%rdg±6dgt, ±5%rdg±6dgt, ±5%rdg±5dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.5933px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 19.5933px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 223pt;\"\u003eRated current\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"891\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 669pt; height: 19.5933px;\"\u003e1.0 to 1.2mA @0.1MΩ \/ 0.25MΩ \/ 0.5MΩ \/ 1MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.5933px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 19.5933px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 223pt;\"\u003eOutput short circuit current\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"891\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 669pt; height: 19.5933px;\"\u003e1.5mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.5933px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 19.5933px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 223pt;\"\u003eLoop impedance\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"891\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 669pt; height: 19.5933px;\"\u003eLOOP ATT, LOOP HIGH, L-PE\/L-N, High current 25A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.5933px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 19.5933px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 223pt;\"\u003eRated voltage\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"891\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 669pt; height: 19.5933px;\"\u003e48 to 500V (50\/60Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.5933px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 19.5933px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 223pt;\"\u003eImpedance range\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"891\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 669pt; height: 19.5933px;\"\u003e20.00\/200.0\/2000Ω, 2.000Ω, 20.00Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.5933px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 19.5933px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 223pt;\"\u003eLoop accuracy\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"891\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 669pt; height: 19.5933px;\"\u003e±3%rdg±6dgt, ±3%rdg±10dgt, ±3%rdg±4dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.5933px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 19.5933px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 223pt;\"\u003ePSC\/PFC Range\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"891\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 669pt; height: 19.5933px;\"\u003e2000A\/20kA, 2000A\/50kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.5933px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 19.5933px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 223pt;\"\u003eRCD Functions\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"891\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 669pt; height: 19.5933px;\"\u003ex1\/2, x1, x5, Ramp, Auto, Uc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.5933px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 19.5933px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 223pt;\"\u003eRCD Types\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"891\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 669pt; height: 19.5933px;\"\u003eAC(G\/S), A(G\/S), F(G\/S), B(G\/S), EV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.5933px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 19.5933px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 223pt;\"\u003eTrip current settings\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"891\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 669pt; height: 19.5933px;\"\u003e10\/30\/100\/300\/500\/1000mA and variable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.5933px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 19.5933px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 223pt;\"\u003eContinuity Range\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"891\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 669pt; height: 19.5933px;\"\u003e20.00\/200.0\/2000Ω (Auto-ranging)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.5933px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 19.5933px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 223pt;\"\u003eContinuity open circuit voltage\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"891\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 669pt; height: 19.5933px;\"\u003e7 to 14V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.5933px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 19.5933px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 223pt;\"\u003eContinuity current\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"891\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 669pt; height: 19.5933px;\"\u003e200mA, 15mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.5933px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 19.5933px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 223pt;\"\u003eContinuity accuracy\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"891\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 669pt; height: 19.5933px;\"\u003e±2%rdg±8dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.5933px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 19.5933px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 223pt;\"\u003eVoltage range\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"891\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 669pt; height: 19.5933px;\"\u003e300.0\/600V (Auto-ranging)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.5933px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 19.5933px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 223pt;\"\u003eVoltage measurement\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"891\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 669pt; height: 19.5933px;\"\u003e2 to 600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.5933px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 19.5933px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 223pt;\"\u003eFrequency range\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"891\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 669pt; height: 19.5933px;\"\u003e45 to 65Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.5933px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 19.5933px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 223pt;\"\u003eVoltage accuracy\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"891\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 669pt; height: 19.5933px;\"\u003e±2%rdg±4dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.5933px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 19.5933px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 223pt;\"\u003eFrequency accuracy\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"891\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 669pt; height: 19.5933px;\"\u003e±0.5%rdg±2dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.5933px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 19.5933px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 223pt;\"\u003ePhase Rotation\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"891\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 669pt; height: 19.5933px;\"\u003e48 to 600V (45 to 65Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.5933px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 19.5933px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 223pt;\"\u003eEarth resistance range\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"891\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 669pt; height: 19.5933px;\"\u003e20.00\/200.0\/2000Ω (Auto-ranging)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.5933px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 19.5933px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 223pt;\"\u003eEarth accuracy\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"891\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 669pt; height: 19.5933px;\"\u003e±2%rdg±0.08Ω \/ ±2%rdg±3dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.5933px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 19.5933px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 223pt;\"\u003eApplicable standards\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"891\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 669pt; height: 19.5933px;\"\u003eIEC 61010-1 CAT IV 300V \/ CAT III 600V, IEC 61557, IEC 60529(IP40), IEC 61326(EMC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.5933px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 19.5933px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 223pt;\"\u003eCommunication interface\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"891\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 669pt; height: 19.5933px;\"\u003eUSB, Bluetooth® 5.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.5933px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 19.5933px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 223pt;\"\u003ePower source\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"891\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 669pt; height: 19.5933px;\"\u003eLR6 (AA) (1.5V) ×8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 19.5933px;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 19.5933px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 223pt;\"\u003eDimensions \/ Weight\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"891\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 669pt; height: 19.5933px;\"\u003e136 × 235 × 114 mm \/ 1350g including batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"39\" style=\"height: 39.1865px;\"\u003e\n\u003ctd height=\"39\" class=\"xl64\" width=\"297\" style=\"height: 39.1865px; border-top-width: medium; border-top-style: none; border-top-color: currentcolor; width: 223pt;\"\u003eAccessories\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"891\" style=\"border-top-width: medium; border-top-style: none; border-top-color: currentcolor; border-left-width: medium; border-left-style: none; border-left-color: currentcolor; width: 669pt; height: 39.1865px;\"\u003eMains test lead, remote control switch lead, distribution board lead, earth resistance leads, auxiliary earth spikes, soft case, carrying case, shoulder strap, shoulder pad, AA batteries, instruction manual, calibration certificate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp data-start=\"698\" data-end=\"1092\"\u003e \u003c\/p\u003e","brand":"CHK Shop","offers":[{"title":"Default Title","offer_id":43984653877313,"sku":"6516BT","price":5649.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/6667\/7825\/files\/6516BT.jpg?v=1779781804"},{"product_id":"kyoritsu-8602evse-test-adaptor","title":"Kyoritsu 8602EVSE Test Adaptor","description":"\u003cp data-start=\"0\" data-end=\"260\"\u003eThe Kyoritsu 8602 EVSE Test Adaptor is a specialised EV charging station test adaptor designed to assist electricians, EV charger installers, and service technicians with the inspection, verification, and troubleshooting of electric vehicle charging systems.\u003c\/p\u003e\n\u003cp data-start=\"262\" data-end=\"628\"\u003eBuilt for testing Mode 3 EV chargers, the 8602 provides a safe and practical interface between the EV charging station and standard electrical test instruments. It allows technicians to simulate vehicle connection states and perform important electrical safety and functional tests during installation, commissioning, and maintenance of EV charging infrastructure.\u003c\/p\u003e\n\u003cp data-start=\"630\" data-end=\"1005\"\u003eThe adaptor is suitable for use with multifunction installation testers and other electrical measuring instruments, helping verify correct charger operation, protective device performance, wiring integrity, and charging functionality. Its compact and durable design makes it ideal for field service work across residential, commercial, and public EV charging installations.\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"891\" style=\"border-collapse: collapse; width: 669pt;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"297\" style=\"mso-width-source: userset; mso-width-alt: 10240; width: 223pt;\"\u003e \u003ccol width=\"594\" style=\"mso-width-source: userset; mso-width-alt: 20480; width: 446pt;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl63\" width=\"297\" style=\"height: 14.6pt; width: 223pt;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl63\" width=\"594\" style=\"border-left: none; width: 446pt;\"\u003e\u003cstrong\u003eDetails\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 14.6pt; border-top: none; width: 223pt;\"\u003ePlug\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"594\" style=\"border-top: none; border-left: none; width: 446pt;\"\u003eIEC 62196-2 Type 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"39\" style=\"height: 29.15pt;\"\u003e\n\u003ctd height=\"39\" class=\"xl64\" width=\"297\" style=\"height: 29.15pt; border-top: none; width: 223pt;\"\u003eRated voltage\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"594\" style=\"border-top: none; border-left: none; width: 446pt;\"\u003eAC 250V Max. (Single-phase)\u003cbr\u003eAC 430V Max. (Three-phase)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 14.6pt; border-top: none; width: 223pt;\"\u003eRated Frequency\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"594\" style=\"border-top: none; border-left: none; width: 446pt;\"\u003e50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"78\" style=\"height: 58.3pt;\"\u003e\n\u003ctd height=\"78\" class=\"xl64\" width=\"297\" style=\"height: 58.3pt; border-top: none; width: 223pt;\"\u003eRated voltage\/current of mains socket\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"594\" style=\"border-top: none; border-left: none; width: 446pt;\"\u003eAC 10A\/250V\u003cbr\u003e8602(EU): Type E socket\u003cbr\u003e8602(UK): Type BF socket\u003cbr\u003e8602(AU): Type O socket\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 14.6pt; border-top: none; width: 223pt;\"\u003eFuse rating\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"594\" style=\"border-top: none; border-left: none; width: 446pt;\"\u003eAC 10A\/250V, Ø5×20mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 14.6pt; border-top: none; width: 223pt;\"\u003eOperating temperature and humidity range\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"594\" style=\"border-top: none; border-left: none; width: 446pt;\"\u003e0 to 40ºC, relative humidity 80% or less (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 14.6pt; border-top: none; width: 223pt;\"\u003eStorage temperature and humidity range\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"594\" style=\"border-top: none; border-left: none; width: 446pt;\"\u003e-10 to 50ºC, relative humidity 80% or less (no condensation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"78\" style=\"height: 58.3pt;\"\u003e\n\u003ctd height=\"78\" class=\"xl64\" width=\"297\" style=\"height: 58.3pt; border-top: none; width: 223pt;\"\u003eApplicable standards\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"594\" style=\"border-top: none; border-left: none; width: 446pt;\"\u003eIEC 61010-1 CAT II 300V\u003cbr\u003eIEC 61010-2-030\u003cbr\u003eIEC 61851-1\u003cbr\u003eIEC 60529 (IP40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 14.6pt; border-top: none; width: 223pt;\"\u003eAltitude\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"594\" style=\"border-top: none; border-left: none; width: 446pt;\"\u003e2000m or less\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 14.6pt; border-top: none; width: 223pt;\"\u003eCable length\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"594\" style=\"border-top: none; border-left: none; width: 446pt;\"\u003eApprox. 250mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"39\" style=\"height: 29.15pt;\"\u003e\n\u003ctd height=\"39\" class=\"xl64\" width=\"297\" style=\"height: 29.15pt; border-top: none; width: 223pt;\"\u003eDimension\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"594\" style=\"border-top: none; border-left: none; width: 446pt;\"\u003eUnit: 172(L) x 105(W) x 57(D) mm\u003cbr\u003ePlug part: 175(L) x 60(W) x 53(D) mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl64\" width=\"297\" style=\"height: 14.6pt; border-top: none; width: 223pt;\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"594\" style=\"border-top: none; border-left: none; width: 446pt;\"\u003eApprox. 840g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"58\" style=\"height: 43.75pt;\"\u003e\n\u003ctd height=\"58\" class=\"xl64\" width=\"297\" style=\"height: 43.75pt; border-top: none; width: 223pt;\"\u003eAccessories\u003c\/td\u003e\n\u003ctd class=\"xl64\" width=\"594\" style=\"border-top: none; border-left: none; width: 446pt;\"\u003e8930 (Fuse [10A\/250V])\u003cbr\u003e9202 (Carrying case)\u003cbr\u003eInstruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"CHK Shop","offers":[{"title":"Default Title","offer_id":43984680648769,"sku":null,"price":1949.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/6667\/7825\/files\/500_1.jpg?v=1779783404"},{"product_id":"kyoritsu-3552bt-insulation-tester-bluetooth","title":"Kyoritsu 3552BT Insulation Tester Bluetooth","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Kyoritsu 3552BT is a compact insulation resistance tester designed for everyday electrical testing and maintenance work. Suitable for electricians, contractors, maintenance technicians, and industrial users, it provides quick and reliable insulation testing for cables, switchboards, motors, and electrical installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe tester offers insulation resistance measurements at 250V, 500V and 1000V, along with continuity and voltage testing functions. Built-in Bluetooth connectivity allows test results to be transferred directly to a smartphone or tablet, making it easier to store records and generate reports without manual data entry.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eA large backlit display, simple rotary selector, and lightweight design make the 3552BT easy to use in the field. Safety features including live circuit detection and automatic discharge help ensure safe operation during testing.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"1330\" style=\"border-collapse: collapse; width: 1001pt;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"190\" span=\"7\" style=\"width: 143pt;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"30\" style=\"height: 22.75pt;\"\u003e\n\u003ctd height=\"30\" class=\"xl65\" width=\"190\" style=\"height: 22.75pt; width: 143pt;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"190\" style=\"border-left: none; width: 143pt;\"\u003e \u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"190\" style=\"border-left: none; width: 143pt;\"\u003e \u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"190\" style=\"border-left: none; width: 143pt;\"\u003e \u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"190\" style=\"border-left: none; width: 143pt;\"\u003e \u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"190\" style=\"border-left: none; width: 143pt;\"\u003e \u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"190\" style=\"border-left: none; width: 143pt;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd colspan=\"7\" height=\"19\" class=\"xl69\" width=\"1330\" style=\"height: 14.6pt; width: 1001pt;\"\u003e\n\u003cdiv style=\"box-sizing: border-box; font-variant-ligatures: normal; font-variant-caps: normal; orphans: 2; widows: 2; -webkit-text-stroke-width: 0px; text-decoration-thickness: initial; text-decoration-style: initial; text-decoration-color: initial;\"\u003e\n\u003cdiv style=\"box-sizing: border-box; margin-right: 0px;\"\u003eInsulation resistance\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl69\" width=\"190\" style=\"height: 14.6pt; border-top: none; width: 143pt;\"\u003eTest voltage\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"190\" style=\"border-top: none; border-left: none; width: 143pt;\"\u003e50V\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"190\" style=\"border-top: none; border-left: none; width: 143pt;\"\u003e100V\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"190\" style=\"border-top: none; border-left: none; width: 143pt;\"\u003e125V\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"190\" style=\"border-top: none; border-left: none; width: 143pt;\"\u003e250V\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"190\" style=\"border-top: none; border-left: none; width: 143pt;\"\u003e500V\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"190\" style=\"border-top: none; border-left: none; width: 143pt;\"\u003e1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl69\" width=\"190\" style=\"height: 14.6pt; border-top: none; width: 143pt;\"\u003eMeasuring range\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"xl67\" width=\"190\" style=\"border-top: none; width: 143pt;\"\u003e100.0MΩ\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"xl67\" width=\"190\" style=\"border-top: none; width: 143pt;\"\u003e200.0MΩ\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"xl67\" width=\"190\" style=\"border-top: none; width: 143pt;\"\u003e250.0MΩ\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"xl67\" width=\"190\" style=\"border-top: none; width: 143pt;\"\u003e500.0MΩ\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"xl67\" width=\"190\" style=\"border-top: none; width: 143pt;\"\u003e20.00GΩ\u003c\/td\u003e\n\u003ctd rowspan=\"2\" class=\"xl67\" width=\"190\" style=\"border-top: none; width: 143pt;\"\u003e40.00GΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl69\" width=\"190\" style=\"height: 14.6pt; border-top: none; width: 143pt;\"\u003e(Auto-ranging)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl69\" width=\"190\" style=\"height: 14.6pt; border-top: none; width: 143pt;\"\u003eMid-scale value\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"190\" style=\"border-top: none; border-left: none; width: 143pt;\"\u003e2MΩ\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"190\" style=\"border-top: none; border-left: none; width: 143pt;\"\u003e5MΩ\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"190\" style=\"border-top: none; border-left: none; width: 143pt;\"\u003e5MΩ\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"190\" style=\"border-top: none; border-left: none; width: 143pt;\"\u003e10MΩ\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"190\" style=\"border-top: none; border-left: none; width: 143pt;\"\u003e100MΩ\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"190\" style=\"border-top: none; border-left: none; width: 143pt;\"\u003e200MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.3pt;\"\u003e\n\u003ctd height=\"38\" class=\"xl69\" width=\"190\" style=\"height: 28.3pt; border-top: none; width: 143pt;\"\u003eFirst effective measuring range\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"190\" style=\"border-top: none; border-left: none; width: 143pt;\"\u003e0.100 to 10.00MΩ\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"190\" style=\"border-top: none; border-left: none; width: 143pt;\"\u003e0.100 to 20.00MΩ\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"190\" style=\"border-top: none; border-left: none; width: 143pt;\"\u003e0.100 to 25.00MΩ\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"190\" style=\"border-top: none; border-left: none; width: 143pt;\"\u003e0.100 to 50.0MΩ\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"190\" style=\"border-top: none; border-left: none; width: 143pt;\"\u003e0.100 to 500MΩ\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"190\" style=\"border-top: none; border-left: none; width: 143pt;\"\u003e0.100 to 1000MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl69\" width=\"190\" style=\"height: 14.6pt; border-top: none; width: 143pt;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"6\" class=\"xl67\" width=\"1140\" style=\"border-left: none; width: 858pt;\"\u003e±2%rdg ±2dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd rowspan=\"2\" height=\"38\" class=\"xl69\" width=\"190\" style=\"height: 29.2pt; border-top: none; width: 143pt;\"\u003eSecond effective measuring range\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"190\" style=\"border-top: none; border-left: none; width: 143pt;\"\u003e0.050 to 0.099MΩ\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"190\" style=\"border-top: none; border-left: none; width: 143pt;\"\u003e0.050 to 0.099MΩ\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"190\" style=\"border-top: none; border-left: none; width: 143pt;\"\u003e0.050 to 0.099MΩ\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"190\" style=\"border-top: none; border-left: none; width: 143pt;\"\u003e0.050 to 0.099MΩ\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"190\" style=\"border-top: none; border-left: none; width: 143pt;\"\u003e0.050 to 0.099MΩ\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"190\" style=\"border-top: none; border-left: none; width: 143pt;\"\u003e0.050 to 0.099MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl67\" width=\"190\" style=\"height: 14.6pt; border-top: none; border-left: none; width: 143pt;\"\u003e10.01 to 100.0MΩ\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"190\" style=\"border-top: none; border-left: none; width: 143pt;\"\u003e20.01 to 200.0MΩ\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"190\" style=\"border-top: none; border-left: none; width: 143pt;\"\u003e25.01 to 250.0MΩ\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"190\" style=\"border-top: none; border-left: none; width: 143pt;\"\u003e50.1 to 500MΩ\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"190\" style=\"border-top: none; border-left: none; width: 143pt;\"\u003e501 to 2000MΩ\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"190\" style=\"border-top: none; border-left: none; width: 143pt;\"\u003e1001 to 4000MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd rowspan=\"2\" height=\"38\" class=\"xl69\" width=\"190\" style=\"height: 29.2pt; border-top: none; width: 143pt;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"6\" class=\"xl67\" width=\"1140\" style=\"border-left: none; width: 858pt;\"\u003e±5%rdg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd colspan=\"6\" height=\"19\" class=\"xl67\" width=\"1140\" style=\"height: 14.6pt; border-left: none; width: 858pt;\"\u003e(0.050 to 0.099MΩ: ±2%rdg±4dgt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl69\" width=\"190\" style=\"height: 14.6pt; border-top: none; width: 143pt;\"\u003eRated current\u003c\/td\u003e\n\u003ctd colspan=\"6\" class=\"xl67\" width=\"1140\" style=\"border-left: none; width: 858pt;\"\u003e1.0 to 1.1mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.3pt;\"\u003e\n\u003ctd height=\"38\" class=\"xl69\" width=\"190\" style=\"height: 28.3pt; border-top: none; width: 143pt;\"\u003eOutput short circuit current\u003c\/td\u003e\n\u003ctd colspan=\"6\" class=\"xl67\" width=\"1140\" style=\"border-left: none; width: 858pt;\"\u003e1.5mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd colspan=\"7\" height=\"19\" class=\"xl69\" width=\"1330\" style=\"height: 14.6pt; width: 1001pt;\"\u003eΩ \/ Continuty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl69\" width=\"190\" style=\"height: 14.6pt; border-top: none; width: 143pt;\"\u003eAuto-ranging\u003c\/td\u003e\n\u003ctd colspan=\"6\" class=\"xl67\" width=\"1140\" style=\"border-left: none; width: 858pt;\"\u003e40.00\/400.0\/4000Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl69\" width=\"190\" style=\"height: 14.6pt; border-top: none; width: 143pt;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"6\" class=\"xl67\" width=\"1140\" style=\"border-left: none; width: 858pt;\"\u003e±2.5%rdg ±8dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.3pt;\"\u003e\n\u003ctd height=\"38\" class=\"xl69\" width=\"190\" style=\"height: 28.3pt; border-top: none; width: 143pt;\"\u003eOutput voltage on open circuit\u003c\/td\u003e\n\u003ctd colspan=\"6\" class=\"xl67\" width=\"1140\" style=\"border-left: none; width: 858pt;\"\u003e5V（4 to 6.9V）\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.3pt;\"\u003e\n\u003ctd height=\"38\" class=\"xl69\" width=\"190\" style=\"height: 28.3pt; border-top: none; width: 143pt;\"\u003eOutput short circuit current\u003c\/td\u003e\n\u003ctd colspan=\"6\" class=\"xl67\" width=\"1140\" style=\"border-left: none; width: 858pt;\"\u003e200mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd colspan=\"7\" height=\"19\" class=\"xl69\" width=\"1330\" style=\"height: 14.6pt; width: 1001pt;\"\u003eVoltage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd rowspan=\"2\" height=\"38\" class=\"xl69\" width=\"190\" style=\"height: 29.2pt; border-top: none; width: 143pt;\"\u003eVoltage range\u003c\/td\u003e\n\u003ctd colspan=\"6\" class=\"xl67\" width=\"1140\" style=\"border-left: none; width: 858pt;\"\u003eAC 2.0 to 600V（45 to 65Hz）\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd colspan=\"6\" height=\"19\" class=\"xl67\" width=\"1140\" style=\"height: 14.6pt; border-left: none; width: 858pt;\"\u003eDC -2.0 to -600V +2.0 to +600V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl69\" width=\"190\" style=\"height: 14.6pt; border-top: none; width: 143pt;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd colspan=\"6\" class=\"xl67\" width=\"1140\" style=\"border-left: none; width: 858pt;\"\u003e±1%rdg ±4dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd colspan=\"7\" height=\"19\" class=\"xl69\" width=\"1330\" style=\"height: 14.6pt; width: 1001pt;\"\u003eGeneral\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd rowspan=\"2\" height=\"38\" class=\"xl69\" width=\"190\" style=\"height: 29.2pt; border-top: none; width: 143pt;\"\u003eApplicable standards\u003c\/td\u003e\n\u003ctd colspan=\"6\" class=\"xl67\" width=\"1140\" style=\"border-left: none; width: 858pt;\"\u003eIEC 61010 CAT Ⅲ 600V \/ CAT Ⅳ 300V, IEC 61010-2-034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd colspan=\"6\" height=\"19\" class=\"xl67\" width=\"1140\" style=\"height: 14.6pt; border-left: none; width: 858pt;\"\u003eIEC61557-1,2,4 IEC61326-1,2-2 IEC60529（IP40）\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl69\" width=\"190\" style=\"height: 14.6pt; border-top: none; width: 143pt;\"\u003ePower source\u003c\/td\u003e\n\u003ctd colspan=\"6\" class=\"xl67\" width=\"1140\" style=\"border-left: none; width: 858pt;\"\u003eLR6\/R6（AA）（1.5V）x4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl69\" width=\"190\" style=\"height: 14.6pt; border-top: none; width: 143pt;\"\u003eCommunication interface\u003c\/td\u003e\n\u003ctd colspan=\"6\" class=\"xl67\" width=\"1140\" style=\"border-left: none; width: 858pt;\"\u003eUSB , Bluetooth®5.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl69\" width=\"190\" style=\"height: 14.6pt; border-top: none; width: 143pt;\"\u003eDimension \/ Weight\u003c\/td\u003e\n\u003ctd colspan=\"6\" class=\"xl67\" width=\"1140\" style=\"border-left: none; width: 858pt;\"\u003e97(L) x 156(W) x 46(D) mm \/ Approx. 490g（including battery）\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"mso-height-source: userset; height: 14.6pt;\"\u003e\n\u003ctd rowspan=\"7\" height=\"133\" class=\"xl69\" width=\"190\" style=\"height: 102.2pt; border-top: none; width: 143pt;\"\u003eAccessories\u003c\/td\u003e\n\u003ctd colspan=\"6\" class=\"xl68\" width=\"1140\" style=\"border-left: none; width: 858pt;\"\u003e\u003ca href=\"https:\/\/www.kew-ltd.co.jp\/en\/products\/detail\/01032\/\"\u003e7260（Test lead with remote control switch）\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"mso-height-source: userset; height: 14.6pt;\"\u003e\n\u003ctd colspan=\"6\" height=\"19\" class=\"xl68\" width=\"1140\" style=\"height: 14.6pt; border-left: none; width: 858pt;\"\u003e\u003ca href=\"https:\/\/www.kew-ltd.co.jp\/en\/products\/detail\/01119\/\"\u003e7261A（Test lead with alligator clip）\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"mso-height-source: userset; height: 14.6pt;\"\u003e\n\u003ctd colspan=\"6\" height=\"19\" class=\"xl68\" width=\"1140\" style=\"height: 14.6pt; border-left: none; width: 858pt;\"\u003e\u003ca href=\"https:\/\/www.kew-ltd.co.jp\/en\/products\/detail\/01031\/\"\u003e8017A（Extension prod long）\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"mso-height-source: userset; height: 14.6pt;\"\u003e\n\u003ctd colspan=\"6\" height=\"19\" class=\"xl68\" width=\"1140\" style=\"height: 14.6pt; border-left: none; width: 858pt;\"\u003e\u003ca href=\"https:\/\/www.kew-ltd.co.jp\/en\/products\/detail\/01126\/\"\u003e9173（Carrying case）\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"mso-height-source: userset; height: 14.6pt;\"\u003e\n\u003ctd colspan=\"6\" height=\"19\" class=\"xl68\" width=\"1140\" style=\"height: 14.6pt; border-left: none; width: 858pt;\"\u003e\u003ca href=\"https:\/\/www.kew-ltd.co.jp\/en\/products\/detail\/01035\/\"\u003e9121（Shoulder strap）\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd colspan=\"6\" height=\"19\" class=\"xl67\" width=\"1140\" style=\"height: 14.6pt; border-left: none; width: 858pt;\"\u003eLR6（AA）（1.5V）x4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd colspan=\"6\" height=\"19\" class=\"xl67\" width=\"1140\" style=\"height: 14.6pt; border-left: none; width: 858pt;\"\u003eInstruction manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"CHK Shop","offers":[{"title":"Default Title","offer_id":43995648491585,"sku":"3552BT","price":2499.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/6667\/7825\/files\/Kyoritsu3552BTInsulationTesterBluetooth.jpg?v=1780055326"},{"product_id":"kyoritsu-6205pro-portable-appliance-tester","title":"Kyoritsu 6205PRO Portable Appliance Tester","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Kyoritsu KEW 6205 is a portable appliance tester designed for fast and efficient electrical safety testing of portable equipment and appliances. Suitable for electricians, test and tag contractors, facility maintenance teams, schools, offices, workshops, and industrial sites, the KEW 6205 helps verify the safety of electrical appliances and ensure compliance with workplace testing requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe instrument provides simple PASS\/FAIL indication, allowing technicians to quickly assess appliance condition without complex setup. A colour backlight display clearly shows test status, helping improve efficiency during routine inspection and testing programs. The unit also supports 10mA and 30mA RCD testing and includes an internal isolation transformer for safe operation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWith onboard memory capable of storing up to 999 test records and printer output functionality, the KEW 6205 simplifies documentation and reporting, making it well suited for contractors and organisations managing large numbers of appliances.\u003c\/span\u003e\u003c\/p\u003e","brand":"CHK Shop","offers":[{"title":"Default Title","offer_id":43995672969281,"sku":"6205PRO","price":3199.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/6667\/7825\/files\/Kyoritsu6205PROPortableApplianceTester.jpg?v=1780057001"},{"product_id":"kyoritsu-6010b-5in1-multifunction-tester","title":"Kyoritsu 6010B 5in1 Multifunction Tester","description":"\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe Kyoritsu 6010B is a versatile multifunction installation tester designed for electrical contractors, maintenance technicians, and inspectors who require multiple electrical tests in a single instrument. Combining five essential testing functions, the 6010B helps simplify electrical installation verification, fault finding, and routine maintenance tasks.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eDesigned for everyday use in commercial, industrial, and residential environments, the instrument provides insulation resistance testing, continuity testing, loop impedance testing, prospective fault current measurement, and voltage measurement. Its straightforward operation and rugged construction make it a practical tool for both commissioning new installations and maintaining existing electrical systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe large digital display and simple rotary selector allow users to quickly switch between test functions, helping improve efficiency when carrying out electrical inspections and compliance testing.\u003c\/span\u003e\u003c\/p\u003e\n\u003ctable border=\"0\" cellpadding=\"0\" cellspacing=\"0\" width=\"572\" style=\"border-collapse: collapse; width: 426pt;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"69\" style=\"width: 51pt;\"\u003e \u003ccol width=\"193\" style=\"mso-width-source: userset; mso-width-alt: 6636; width: 144pt;\"\u003e \u003ccol width=\"149\" style=\"mso-width-source: userset; mso-width-alt: 5120; width: 111pt;\"\u003e \u003ccol width=\"161\" style=\"mso-width-source: userset; mso-width-alt: 5533; width: 120pt;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr height=\"30\" style=\"height: 22.75pt;\"\u003e\n\u003ctd height=\"30\" class=\"xl66\" width=\"69\" style=\"height: 22.75pt; width: 51pt;\"\u003e \u003c\/td\u003e\n\u003ctd class=\"xl65\" width=\"193\" style=\"border-left: none; width: 144pt;\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"149\" style=\"border-left: none; width: 111pt;\"\u003e \u003c\/td\u003e\n\u003ctd class=\"xl66\" width=\"161\" style=\"border-left: none; width: 120pt;\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd colspan=\"4\" height=\"19\" class=\"xl68\" width=\"572\" style=\"height: 14.6pt; width: 426pt;\"\u003e\n\u003cdiv style=\"box-sizing: border-box; font-variant-ligatures: normal; font-variant-caps: normal; orphans: 2; widows: 2; -webkit-text-stroke-width: 0px; text-decoration-thickness: initial; text-decoration-style: initial; text-decoration-color: initial;\"\u003eContinuity Testing\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.3pt;\"\u003e\n\u003ctd rowspan=\"4\" height=\"95\" class=\"xl68\" width=\"69\" style=\"height: 72.1pt; border-top: none; width: 51pt;\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl70\" width=\"342\" style=\"border-left: none; width: 255pt;\"\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd class=\"xl71\" width=\"161\" style=\"border-top: none; border-left: none; width: 120pt;\"\u003e20\/200Ω (Auto-Ranging)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd colspan=\"2\" height=\"19\" class=\"xl70\" width=\"342\" style=\"height: 14.6pt; border-left: none; width: 255pt;\"\u003eOpen Circuit Voltage\u003c\/td\u003e\n\u003ctd class=\"xl71\" width=\"161\" style=\"border-top: none; border-left: none; width: 120pt;\"\u003e\u0026gt; 6V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd colspan=\"2\" height=\"19\" class=\"xl70\" width=\"342\" style=\"height: 14.6pt; border-left: none; width: 255pt;\"\u003eShort Circuit Current\u003c\/td\u003e\n\u003ctd class=\"xl71\" width=\"161\" style=\"border-top: none; border-left: none; width: 120pt;\"\u003e\u0026gt; 200mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd colspan=\"2\" height=\"19\" class=\"xl70\" width=\"342\" style=\"height: 14.6pt; border-left: none; width: 255pt;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd class=\"xl71\" width=\"161\" style=\"border-top: none; border-left: none; width: 120pt;\"\u003e±(3%rdg + 3dgt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd colspan=\"4\" height=\"19\" class=\"xl68\" width=\"572\" style=\"height: 14.6pt; width: 426pt;\"\u003eInsulation Resistance Testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.3pt;\"\u003e\n\u003ctd rowspan=\"5\" height=\"114\" class=\"xl68\" width=\"69\" style=\"height: 86.7pt; border-top: none; width: 51pt;\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl70\" width=\"342\" style=\"border-left: none; width: 255pt;\"\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd class=\"xl71\" width=\"161\" style=\"border-top: none; border-left: none; width: 120pt;\"\u003e20\/200MΩ (Auto-Ranging)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd colspan=\"2\" height=\"19\" class=\"xl70\" width=\"342\" style=\"height: 14.6pt; border-left: none; width: 255pt;\"\u003eTest Voltage\u003c\/td\u003e\n\u003ctd class=\"xl71\" width=\"161\" style=\"border-top: none; border-left: none; width: 120pt;\"\u003e500\/1000V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd colspan=\"2\" height=\"19\" class=\"xl70\" width=\"342\" style=\"height: 14.6pt; border-left: none; width: 255pt;\"\u003eOpen Circuit Voltage\u003c\/td\u003e\n\u003ctd class=\"xl71\" width=\"161\" style=\"border-top: none; border-left: none; width: 120pt;\"\u003e+20 to 0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd colspan=\"2\" height=\"19\" class=\"xl70\" width=\"342\" style=\"height: 14.6pt; border-left: none; width: 255pt;\"\u003eRated Current\u003c\/td\u003e\n\u003ctd class=\"xl71\" width=\"161\" style=\"border-top: none; border-left: none; width: 120pt;\"\u003e\u0026gt; 1mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd colspan=\"2\" height=\"19\" class=\"xl70\" width=\"342\" style=\"height: 14.6pt; border-left: none; width: 255pt;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd class=\"xl71\" width=\"161\" style=\"border-top: none; border-left: none; width: 120pt;\"\u003e± (3%rdg + 3dgt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd colspan=\"4\" height=\"19\" class=\"xl68\" width=\"572\" style=\"height: 14.6pt; width: 426pt;\"\u003eLoop Impedance Testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd rowspan=\"5\" height=\"133\" class=\"xl68\" width=\"69\" style=\"height: 100.4pt; border-top: none; width: 51pt;\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl70\" width=\"342\" style=\"border-left: none; width: 255pt;\"\u003eImpedance Range\u003c\/td\u003e\n\u003ctd class=\"xl71\" width=\"161\" style=\"border-top: none; border-left: none; width: 120pt;\"\u003e20\/2000Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.3pt;\"\u003e\n\u003ctd colspan=\"2\" height=\"38\" class=\"xl70\" width=\"342\" style=\"height: 28.3pt; border-left: none; width: 255pt;\"\u003eRated Voltage\u003c\/td\u003e\n\u003ctd class=\"xl71\" width=\"161\" style=\"border-top: none; border-left: none; width: 120pt;\"\u003e230V + 10 to 15%(50Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd colspan=\"2\" rowspan=\"2\" height=\"57\" class=\"xl70\" width=\"342\" style=\"height: 42.9pt; width: 255pt;\"\u003eNormal Test Current\u003c\/td\u003e\n\u003ctd class=\"xl71\" width=\"161\" style=\"border-top: none; border-left: none; width: 120pt;\"\u003e20Ω:25A\/10ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.3pt;\"\u003e\n\u003ctd height=\"38\" class=\"xl71\" width=\"161\" style=\"height: 28.3pt; border-top: none; border-left: none; width: 120pt;\"\u003e2000Ω:15mA\/350ms max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd colspan=\"2\" height=\"19\" class=\"xl70\" width=\"342\" style=\"height: 14.6pt; border-left: none; width: 255pt;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd class=\"xl71\" width=\"161\" style=\"border-top: none; border-left: none; width: 120pt;\"\u003e±(3%rdg + 8dgt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd colspan=\"4\" height=\"19\" class=\"xl68\" width=\"572\" style=\"height: 14.6pt; width: 426pt;\"\u003eRCD Testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.3pt;\"\u003e\n\u003ctd rowspan=\"10\" height=\"304\" class=\"xl68\" width=\"69\" style=\"height: 229.1pt; border-top: none; width: 51pt;\"\u003e \u003c\/td\u003e\n\u003ctd class=\"xl70\" width=\"193\" style=\"border-top: none; border-left: none; width: 144pt;\"\u003eTest Current\u003c\/td\u003e\n\u003ctd class=\"xl70\" width=\"149\" style=\"border-top: none; border-left: none; width: 111pt;\"\u003ex1\/2, x1\u003c\/td\u003e\n\u003ctd class=\"xl71\" width=\"161\" style=\"border-top: none; border-left: none; width: 120pt;\"\u003e10, 30, 100, 300, 500mA (2000ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl70\" width=\"193\" style=\"height: 14.6pt; border-top: none; border-left: none; width: 144pt;\"\u003e(Test Current Duration)\u003c\/td\u003e\n\u003ctd class=\"xl70\" width=\"149\" style=\"border-top: none; border-left: none; width: 111pt;\"\u003eFast\u003c\/td\u003e\n\u003ctd class=\"xl71\" width=\"161\" style=\"border-top: none; border-left: none; width: 120pt;\"\u003e150mA (50ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"57\" style=\"height: 42.45pt;\"\u003e\n\u003ctd height=\"57\" class=\"xl70\" width=\"193\" style=\"height: 42.45pt; border-top: none; border-left: none; width: 144pt;\"\u003e \u003c\/td\u003e\n\u003ctd class=\"xl70\" width=\"149\" style=\"border-top: none; border-left: none; width: 111pt;\"\u003eDC\u003c\/td\u003e\n\u003ctd class=\"xl71\" width=\"161\" style=\"border-top: none; border-left: none; width: 120pt;\"\u003e10, 30, 100, 300mA (2000ms), 500mA (200ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"57\" style=\"height: 42.45pt;\"\u003e\n\u003ctd height=\"57\" class=\"xl70\" width=\"193\" style=\"height: 42.45pt; border-top: none; border-left: none; width: 144pt;\"\u003e \u003c\/td\u003e\n\u003ctd class=\"xl70\" width=\"149\" style=\"border-top: none; border-left: none; width: 111pt;\"\u003eAuto Ramp\u003c\/td\u003e\n\u003ctd class=\"xl71\" width=\"161\" style=\"border-top: none; border-left: none; width: 120pt;\"\u003eGoes up by 10% from 20% to 110% of IΔn. 300ms×10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.3pt;\"\u003e\n\u003ctd colspan=\"2\" height=\"38\" class=\"xl70\" width=\"342\" style=\"height: 28.3pt; border-left: none; width: 255pt;\"\u003eRated Voltage\u003c\/td\u003e\n\u003ctd class=\"xl71\" width=\"161\" style=\"border-top: none; border-left: none; width: 120pt;\"\u003e230V + 10 to 15% [50Hz]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd rowspan=\"5\" height=\"95\" class=\"xl70\" width=\"193\" style=\"height: 73.0pt; border-top: none; width: 144pt;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd rowspan=\"4\" class=\"xl70\" width=\"149\" style=\"border-top: none; width: 111pt;\"\u003eTest Current\u003c\/td\u003e\n\u003ctd class=\"xl71\" width=\"161\" style=\"border-top: none; border-left: none; width: 120pt;\"\u003ex1\/2: -8 to 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl71\" width=\"161\" style=\"height: 14.6pt; border-top: none; border-left: none; width: 120pt;\"\u003ex1, FAST: +2%+8%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl71\" width=\"161\" style=\"height: 14.6pt; border-top: none; border-left: none; width: 120pt;\"\u003eDC: ±10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl71\" width=\"161\" style=\"height: 14.6pt; border-top: none; border-left: none; width: 120pt;\"\u003eAuto Ramp: ±4%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl70\" width=\"149\" style=\"height: 14.6pt; border-top: none; border-left: none; width: 111pt;\"\u003eTrip Time\u003c\/td\u003e\n\u003ctd class=\"xl71\" width=\"161\" style=\"border-top: none; border-left: none; width: 120pt;\"\u003e±(1%rdg + 3dgt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd colspan=\"4\" height=\"19\" class=\"xl68\" width=\"572\" style=\"height: 14.6pt; width: 426pt;\"\u003eUc Testing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd rowspan=\"6\" height=\"171\" class=\"xl68\" width=\"69\" style=\"height: 128.7pt; border-top: none; width: 51pt;\"\u003e \u003c\/td\u003e\n\u003ctd colspan=\"2\" class=\"xl70\" width=\"342\" style=\"border-left: none; width: 255pt;\"\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd class=\"xl71\" width=\"161\" style=\"border-top: none; border-left: none; width: 120pt;\"\u003e100V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.3pt;\"\u003e\n\u003ctd colspan=\"2\" height=\"38\" class=\"xl70\" width=\"342\" style=\"height: 28.3pt; border-left: none; width: 255pt;\"\u003eRated Voltage\u003c\/td\u003e\n\u003ctd class=\"xl71\" width=\"161\" style=\"border-top: none; border-left: none; width: 120pt;\"\u003e230V + 10 to 15% (50Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd colspan=\"2\" rowspan=\"3\" height=\"95\" class=\"xl70\" width=\"342\" style=\"height: 71.2pt; width: 255pt;\"\u003eTest Current\u003c\/td\u003e\n\u003ctd class=\"xl71\" width=\"161\" style=\"border-top: none; border-left: none; width: 120pt;\"\u003e5mA at IΔn = 10mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.3pt;\"\u003e\n\u003ctd height=\"38\" class=\"xl71\" width=\"161\" style=\"height: 28.3pt; border-top: none; border-left: none; width: 120pt;\"\u003e15mA at IΔn = 30\/100mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.3pt;\"\u003e\n\u003ctd height=\"38\" class=\"xl71\" width=\"161\" style=\"height: 28.3pt; border-top: none; border-left: none; width: 120pt;\"\u003e150mA at IΔn = 300\/500mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd colspan=\"2\" height=\"19\" class=\"xl70\" width=\"342\" style=\"height: 14.6pt; border-left: none; width: 255pt;\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd class=\"xl71\" width=\"161\" style=\"border-top: none; border-left: none; width: 120pt;\"\u003e+5% +15%rdg±8dgt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"113\" style=\"height: 84.9pt;\"\u003e\n\u003ctd colspan=\"3\" height=\"113\" class=\"xl68\" width=\"411\" style=\"height: 84.9pt; width: 306pt;\"\u003eApplicable standards\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"161\" style=\"border-top: none; border-left: none; width: 120pt;\"\u003eIEC 61010-1 CAT Ⅲ 300V Pollution Degree 2, IEC 61010-2-034, IEC 61557-1, 2, 3, 4, 6, 10, IEC 60529 (IP40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd colspan=\"3\" height=\"19\" class=\"xl68\" width=\"411\" style=\"height: 14.6pt; width: 306pt;\"\u003ePower source\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"161\" style=\"border-top: none; border-left: none; width: 120pt;\"\u003eR6\/LR6 × 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.3pt;\"\u003e\n\u003ctd colspan=\"3\" height=\"38\" class=\"xl68\" width=\"411\" style=\"height: 28.3pt; width: 306pt;\"\u003eDimension\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"161\" style=\"border-top: none; border-left: none; width: 120pt;\"\u003e115(L) × 175(W) × 86(D)mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd colspan=\"3\" height=\"19\" class=\"xl68\" width=\"411\" style=\"height: 14.6pt; width: 306pt;\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"xl67\" width=\"161\" style=\"border-top: none; border-left: none; width: 120pt;\"\u003eApprox. 840g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd colspan=\"3\" rowspan=\"7\" height=\"192\" class=\"xl68\" width=\"411\" style=\"height: 145.0pt; width: 306pt;\"\u003eAccessories\u003c\/td\u003e\n\u003ctd class=\"xl69\" width=\"161\" style=\"border-top: none; border-left: none; width: 120pt;\"\u003e\u003ca href=\"https:\/\/www.kew-ltd.co.jp\/en\/products\/detail\/00118\/\"\u003e7122B (Test leads)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"39\" style=\"height: 29.15pt;\"\u003e\n\u003ctd height=\"39\" class=\"xl69\" width=\"161\" style=\"height: 29.15pt; border-top: none; border-left: none; width: 120pt;\"\u003e\u003ca href=\"https:\/\/www.kew-ltd.co.jp\/en\/products\/detail\/00497\/\"\u003eKAMP10 (Test lead with IEC connector)*1\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"39\" style=\"height: 29.15pt;\"\u003e\n\u003ctd height=\"39\" class=\"xl69\" width=\"161\" style=\"height: 29.15pt; border-top: none; border-left: none; width: 120pt;\"\u003e\u003ca href=\"https:\/\/www.kew-ltd.co.jp\/en\/products\/detail\/01223\/\"\u003e8923 (Fuse[0.5A\/600V] × 1 (included), 1 (spare)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl69\" width=\"161\" style=\"height: 14.6pt; border-top: none; border-left: none; width: 120pt;\"\u003e\u003ca href=\"https:\/\/www.kew-ltd.co.jp\/en\/products\/detail\/01228\/\"\u003e9092 (Cord case)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl69\" width=\"161\" style=\"height: 14.6pt; border-top: none; border-left: none; width: 120pt;\"\u003e\u003ca href=\"https:\/\/www.kew-ltd.co.jp\/en\/products\/detail\/01035\/\"\u003e9121 (Shoulder strap)\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"19\" style=\"height: 14.6pt;\"\u003e\n\u003ctd height=\"19\" class=\"xl67\" width=\"161\" style=\"height: 14.6pt; border-top: none; border-left: none; width: 120pt;\"\u003eShoulder pad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr height=\"38\" style=\"height: 28.3pt;\"\u003e\n\u003ctd height=\"38\" class=\"xl67\" width=\"161\" style=\"height: 28.3pt; border-top: none; border-left: none; width: 120pt;\"\u003eInstruction manual, R6(AA) × 8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"CHK Shop","offers":[{"title":"Default Title","offer_id":43995673952321,"sku":"6010B","price":2049.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0660\/6667\/7825\/files\/Kyoritsu6010B5in1MultifunctionTester.jpg?v=1780057156"}],"url":"https:\/\/www.chkshop.com.au\/collections\/clearance.oembed","provider":"CHK Shop","version":"1.0","type":"link"}